Cookie Settings

We use cookies to optimize our website. These include cookies that are necessary for the operation of the site, as well as those that are only used for anonymous statistic. You can decide for yourself which categories you want to allow. Further information can be found in our data privacy protection .

Essential

These cookies are necessary to run the core functionalities of this website and cannot be disabled.

Name Webedition CMS
Purpose This cookie is required by the CMS (Content Management System) Webedition for the system to function correctly. Typically, this cookie is deleted when the browser is closed.
Name econda
Purpose Session cookie emos_jcsid for the web analysis software econda. This runs in the “anonymized measurement” mode. There is no personal reference. As soon as the user leaves the site, tracking is ended and all data in the browser are automatically deleted.
Statistics

These cookies help us understand how visitors interact with our website by collecting and analyzing information anonymously. Depending on the tool, one or more cookies are set by the provider.

Name econda
Purpose Statistics
External media

Content from external media platforms is blocked by default. If cookies from external media are accepted, access to this content no longer requires manual consent.

Name YouTube
Purpose Show YouTube content
Name Twitter
Purpose activate Twitter Feeds

Publications highlights - Applications in Interventional Healthcare

Miniaturized electromagnetic tracking enables efficient ultrasound-navigated needle insertions

Ultrasound (US) has gained popularity as a guidance modality for percutaneous needle insertions because it is widely available and non-ionizing. However, coordinating scanning and needle insertion still requires significant experience. Current assistance solutions utilize optical or electromagnetic tracking (EMT) technology directly integrated into the US device or probe. This results in specialized devices or introduces additional hardware, limiting the ergonomics of both the scanning and insertion process. We developed the first ultrasound (US) navigation solution designed to be used as a non-permanent accessory for existing US devices while maintaining the ergonomics during the scanning process. A miniaturized EMT source is reversibly attached to the US probe, temporarily creating a combined modality that provides real-time anatomical imaging and instrument tracking at the same time. Studies performed with 11 clinical operators show that the proposed navigation solution can guide needle insertions with a targeting accuracy of about 5 mm, which is comparable to existing approaches and unaffected by repeated attachment and detachment of the miniaturized tracking solution. The assistance proved particularly helpful for non-expert users and needle insertions performed outside of the US plane. The small size and reversible attachability of the proposed navigation solution promises streamlined integration into the clinical workflow and widespread access to US navigated punctures.

Seitel, A., Groener, D., Eisenmann, M., Aguilera Saiz, L., Pekdemir, B., Sridharan, P., Nguyen, C. T., Häfele, S., Feldmann, C., Everitt, B., Happel, C., Herrmann, E., Sabet, A., Grünwald, F., Franz, A. M., & Maier-Hein, L. (2024). Miniaturized electromagnetic tracking enables efficient ultrasound-navigated needle insertions. Scientific Reports, 14(1) [pdf]

© dkfz.de

Spectral imaging enables contrast agent-free real-time ischemia monitoring in laparoscopic surgery

Laparoscopic surgery has evolved as a key technique for cancer diagnosis and therapy. While characterization of the tissue perfusion is crucial in various procedures, such as partial nephrectomy, doing so by means of visual inspection remains highly challenging. We developed a laparoscopic real-time multispectral imaging system featuring a compact and lightweight multispectral camera and the possibility to complement the conventional surgical view of the patient with functional information at a video rate of 25 Hz. To enable contrast agent–free ischemia monitoring during laparoscopic partial nephrectomy, we phrase the problem of ischemia detection as an out-of-distribution detection problem that does not rely on data from any other patient and uses an ensemble of invertible neural networks at its core. An in-human trial demonstrates the feasibility of our approach and highlights the potential of spectral imaging combined with advanced deep learning–based analysis tools for fast, efficient, reliable, and safe functional laparoscopic imaging.

Ayala, L., Adler, T. J., Seidlitz, S., Wirkert, S., Engels, C., Seitel, A., Sellner, J., Aksenov, A., Bodenbach, M., Bader, P., Baron, S., Vemuri, A., Wiesenfarth, M., Schreck, N., Mindroc, D., Tizabi, M., Pirmann, S., Everitt, B., Kopp-Schneider, A., ... Maier-Hein, L. (2023). Spectral imaging enables contrast agent–free real-time ischemia monitoring in laparoscopic surgery. Science Advances, 9(10). [pdf]

© dkfz.de

Sources of performance variability in deep learning-based polyp detection

Purpose: Validation metrics are a key prerequisite for the reliable tracking of scientific progress and for deciding on the potential clinical translation of methods. While recent initiatives aim to develop comprehensive theoretical frameworks for understanding metric-related pitfalls in image analysis problems, there is a lack of experimental evidence on the concrete effects of common and rare pitfalls on specific applications. We address this gap in the literature in the context of colon cancer screening.

Methods: Our contribution is twofold. Firstly, we present the winning solution of the Endoscopy Computer Vision Challenge on colon cancer detection, conducted in conjunction with the IEEE International Symposium on Biomedical Imaging 2022. Secondly, we demonstrate the sensitivity of commonly used metrics to a range of hyperparameters as well as the consequences of poor metric choices.

Results: Based on comprehensive validation studies performed with patient data from six clinical centers, we found all commonly applied object detection metrics to be subject to high inter-center variability. Furthermore, our results clearly demonstrate that the adaptation of standard hyperparameters used in the computer vision community does not generally lead to the clinically most plausible results. Finally, we present localization criteria that correspond well to clinical relevance.

Conclusion: We conclude from our study that (1) performance results in polyp detection are highly sensitive to various design choices, (2) common metric configurations do not reflect the clinical need and rely on suboptimal hyperparameters and (3) comparison of performance across datasets can be largely misleading. Our work could be a first step towards reconsidering common validation strategies in deep learning-based colonoscopy and beyond.

Tran, T. N., Adler, T. J., Yamlahi, A., Christodoulou, E., Godau, P., Reinke, A., Tizabi, M. D., Sauer, P., Persicke, T., Albert, J. G., & Maier-Hein, L. (2023). Sources of performance variability in deep learning-based polyp detection. International Journal of Computer Assisted Radiology and Surgery, 18(7) [pdf].

© dkfz.de

Robust hand tracking for surgical telestration

Purpose: As human failure has been shown to be one primary cause for post-operative death, surgical training is of the utmost socioeconomic importance. In this context, the concept of surgical telestration has been introduced to enable experienced surgeons to efficiently and effectively mentor trainees in an intuitive way. While previous approaches to telestration have concentrated on overlaying drawings on surgical videos, we explore the augmented reality (AR) visualization of surgical hands to imitate the direct interaction with the situs.
Methods: We present a real-time hand tracking pipeline specifically designed for the application of surgical telestration. It comprises three modules, dedicated to (1) the coarse localization of the expert's hand and the subsequent (2) segmentation of the hand for AR visualization in the field of view of the trainee and (3) regression of keypoints making up the hand's skeleton. The semantic representation is obtained to offer the ability for structured reporting of the motions performed as part of the teaching.
Results: According to a comprehensive validation based on a large data set comprising more than 14,000 annotated images with varying application-relevant conditions, our algorithm enables real-time hand tracking and is sufficiently accurate for the task of surgical telestration. In a retrospective validation study, a mean detection accuracy of 98%, a mean keypoint regression accuracy of 10.0 px and a mean Dice Similarity Coefficient of 0.95 were achieved. In a prospective validation study, it showed uncompromised performance when the sensor, operator or gesture varied.
Conclusion: Due to its high accuracy and fast inference time, our neural network-based approach to hand tracking is well suited for an AR approach to surgical telestration. Future work should be directed to evaluating the clinical value of the approach.

Müller, L.-R., Petersen, J., Yamlahi, A., Wise, P., Adler, T. J., Seitel, A., Kowalewski, K.-F., Müller, B., Kenngott, H., Nickel, F., & Maier-Hein, L. (2022). Robust hand tracking for surgical telestration. International Journal of Computer Assisted Radiology and Surgery, 17(8), 1477–1486. [pdf]

© dkfz.de

to top
powered by webEdition CMS